Type SJT 300 Volts CSA UL

 

Fully-annealed, stranded bare copper per ASTM B-174, colour-coded polyvinyl chloride PVC insulation, Black polyvinyl chloride PVC jacket. -20° C to 60° C, 300 Volts, CSA FT1 and UL Approved.

Packaging: 300m, 150m & 75m spools, or cut to length.

Applications:

PCS
Catalogue
Number
Conductor AMPS* Wall Thickness Nominal
O.D.
(inches)
Total
Weight
(lbs/km)

Colour Code Chart
No. AWG
Size
Stranding Insulation
(inches)
Jacket
(inches)
SJT18-02 2 18 16 x 30 10 .030 .030 .285 137 1
SJT18-03 3 18 16 x 30 10 .030 .030 .300 167 1
SJT18-04 4 18 16 x 30 7 .030 .030 .330 223 1
SJT16-02 2 16 26 x 30 13 .030 .030 .309 167 1
SJT16-03 3 16 26 x 30 13 .030 .030 .327 236 1
SJT16-04 4 16 26 x 30 10 .030 .030 .359 279 1

 

*Ampacities (Amps per conductor) are based on 30°C ambient temperature in air per the 1999 NEC, Table 400-5(A). Ampacities for 3/C and 4/C cords assume 1 conductor is used as a ground or neutral and does not carry current. Ampacities for 5/C cords assume 2 conductors are used as ground and neutral and do not carry current.

 

Applications:

Designed for hard usage with portable tools, small motors and power extensions.