Type SOOW 600 Volts CSA UL 

Blasting Cable Red Jacket

 

Fully-annealed, stranded bare copper per ASTM B-174, premium grade colour-coded 90ºC synthetic rubber insulation, oil resistant Thermoset (Black CPE) Jacket. -40° C to 90° C, 600 Volts, CSA FT1 and UL approved, sunlight, water, and weather resistant per UL & CSA.

Packaging: 300m, 150m & 75m spools, or cut to length.

Applications:

PCS
Catalogue
Number
Conductor AMPS* Wall Thickness Nominal
O.D.
(inches)
Total
Weight
(lbs/km)

Colour Code Chart
No. AWG
Size
Stranding Insulation
(inches)
Jacket
(inches)

SOOW12-02-02

2 12 65 x 30 25 .045 .095 .565 371 1

 

*Ampacities (Amps per conductor) are based on 30°C ambient temperature in air per the 1999 NEC, Table 400-5(A). Ampacities for 3/C and 4/C cords assume 1 conductor is used as a ground or neutral and does not carry current. Ampacities for 5/C cords assume 2 conductors are used as ground and neutral and do not carry current.

 

Applications:

Designed as a power lead for explosive devices.