Type SOOW Multi-Conductor Control Cable

600 Volts CSA UL

 

Fully-annealed, stranded bare copper per ASTM B-174, premium grade colour-coded 90ºC synthetic rubber insulation, oil resistant Thermoset (Black CPE) Jacket. -40° C to 90° C, 600 Volts, CSA FT1 and UL approved, sunlight, water, and weather resistant per UL & CSA.

Packaging: Long length reels, cut to length.

Applications:

PCS
Catalogue
Number
Conductor AMPS* Wall Thickness Nominal
O.D.
(inches)
Total
Weight
(lbs/km)

Colour Code Chart
No. AWG
Size
Stranding Insulation
(inches)
Jacket
(inches)
SOOW18-06 6 18 16 x 30 5.6 .030 .080 .490 450 2
SOOW18-07 7 18 16 x 30 4.9 .030 .080 .490 482 2
SOOW18-08 8 18 16 x 30 4.9 .030 .080 .523 515 2
SOOW18-09 9 18 16 x 30 4.9 .030 .080 557 587 2
SOOW18-10 10 18 16 x 30 3.5 .030 .080 .577 679 2
SOOW18-12 12 18 16 x 30 3.5 .030 .080 .605 761 2
SOOW18-14 14 18 16 x 30 3.5 .030 .080 .640 869 2
SOOW18-16 16 18 16 x 30 3.5 .030 .095 .704 984 2
SOOW18-18 18 18 16 x 30 3.5 .030 .095 .735 1,115 2
SOOW18-20 20 18 16 x 30 3.5 .030 .095 .750 1,247 2
SOOW18-24 24 18 16 x 30 3.1 .030 .095 .810 1,378 2
SOOW18-30 30 18 16 x 30 3.1 .030 .095 .885 1,673 2
SOOW18-37 37 18 16 x 30 2.8 .030 .110 .980 1,969 2
SOOW18-50 50 18 16 x 30 2.5 .030 .110 1.100 2,664 2
SOOW16-06 6 16 26 x 30 8 .030 .080 .520 590 2
SOOW16-07 7 16 26 x 30 7 .030 .080 .520 623 2
SOOW16-08 8 16 26 x 30 7 .030 .080 .565 689 2
SOOW16-09 9 16 26 x 30 7 .030 .080 .600 738 2
SOOW16-10 10 16 26 x 30 5 .030 .080 .620 833 2
SOOW16-12 12 16 26 x 30 5 .030 .080 .650 1,010 2
SOOW16-14 14 16 26 x 30 5 .030 .080 .725 1,158 2
SOOW16-16 16 16 26 x 30 5 .030 .095 .760 1,325 2
SOOW16-18 18 16 26 x 30 5 .030 .095 .795 1,427 2
SOOW16-20 20 16 26 x 30 5 .030 .095 .815 1,594 2
SOOW16-24 24 16 26 x 30 4.5 .030 .095 .880 1,827 2
SOOW16-30 30 16 26 x 30 4.5 .030 .110 .990 2,398 2
SOOW16-36 36 16 26 x 30 4 .030 .110 1.065 2,657 2
SOOW16-37 37 16 26 x 30 4 .030 .110 1.065 2,690 2
SOOW16-39 39 16 26 x 30 4 .030 .110 1.080 2,750 2
SOOW16-40 40 16 26 x 30 4 .030 .110 1.100 2,789 2
SOOW16-44 44 16 26 x 30 4 .030 .110 1.150 3,196 2
SOOW16-60 60 16 26 x 30 3.5 .030 .125 1.325 4,183 2

 

*Ampacities (Amps per conductor) are based on 30°C ambient temperature in air per the 1999 NEC, Table 400-5(A). Ampacities for 3/C and 4/C cords assume 1 conductor is used as a ground or neutral and does not carry current. Ampacities for 5/C cords assume 2 conductors are used as ground and neutral and do not carry current.

 

Applications:

Designed for use in remote control of equipment by push-button stations, signal circuits and control systems in
industrial plants, breweries, theatres, steel mills, process facilities and construction sites. Production line push button controls, systems and alarms.