IMSA 19-3 Traffic Signal Control Cable

Figure 8 Unshielded

Stranded or solid bare copper conductor, colour coded PVC polyvinyl chloride  insulation,  polyester binder tape, Black sunlight resistant PVC jacket.  -30° C to 75° C, 600 Volts. Integrated Messenger - 1/4″ (.250″) 7-wire extra high strength (6,650 lb. test) flooded galvanized steel strand.

Packaging: 1500m, 300m, & 150m Spools.

Applications:

PCS
Catalogue
Number

Conductor

Wall Thickness

(inches)

Jacket Thickness

(inches)

Nominal
O.D.
(inches)
Total
Weight
(lbs/km)

Colour Code Chart
No. AWG
Size
Stranding
I19-3-14-04CB0* 4 14 Solid .025 .045 .383 X .737 557 2
I19-3-14-07CA0 7 14 7 .025 .045 .475 x .945 1,053 2
I19-3-14-09CB0 9 14 Solid .025 .045 .520 x .990 1,168 2
I19-3-12-02CA0* 2 12 7 .025 .045 .405 x .759 557 2
I19-3-12-05CA0 5 12 7 .025 .045 .511 x .981 722 2

 

*Utilizes 0.134″ (3.4mm) solid extra high strength (2,800 lb. test) galvanized steel wire which is permitted for

cables 12 AWG, 3 conductors or less, or 14 AWG, 4 conductors or less.

 

Applications: