IMSA 19-3 Traffic Signal Control Cable Figure 8 Unshielded |
![]() |

|
Stranded or solid bare copper conductor, colour coded PVC polyvinyl chloride insulation, polyester binder tape, Black sunlight resistant PVC jacket. -30° C to 75° C, 600 Volts. Integrated Messenger - 1/4″ (.250″) 7-wire extra high strength (6,650 lb. test) flooded galvanized steel strand. Packaging: 1500m, 300m, & 150m Spools. |
| PCS Catalogue Number |
Conductor |
Wall Thickness (inches) |
Jacket Thickness (inches) | Nominal O.D. (inches) | Total Weight (lbs/km) | Colour Code Chart | ||
|---|---|---|---|---|---|---|---|---|
| No. | AWG Size | Stranding | ||||||
| I19-3-14-04CB0* | 4 | 14 | Solid | .025 | .045 | .383 X .737 | 557 | 2 |
| I19-3-14-07CA0 | 7 | 14 | 7 | .025 | .045 | .475 x .945 | 1,053 | 2 |
| I19-3-14-09CB0 | 9 | 14 | Solid | .025 | .045 | .520 x .990 | 1,168 | 2 |
| I19-3-12-02CA0* | 2 | 12 | 7 | .025 | .045 | .405 x .759 | 557 | 2 |
| I19-3-12-05CA0 | 5 | 12 | 7 | .025 | .045 | .511 x .981 | 722 | 2 |
|
*Utilizes 0.134″ (3.4mm) solid extra high strength (2,800 lb. test) galvanized steel wire which is permitted for cables 12 AWG, 3 conductors or less, or 14 AWG, 4 conductors or less.
Outdoor or indoor use in traffic signal, traffic control systems, fire alarm systems, underground conduit and aerial use with messenger. -30° C to 75° C, 600 Volts. Wet or dry locations. |